NUKLEONIKA 2000, 45(3):189-191
FAST NEUTRON ACTIVATION ANALYSIS OF GOLD BY INELASTIC SCATTERING, 197Au(N,N'g)197Aum, BY MEANS OF PLASMA FOCUS DEVICEGiovanni Verri1, Franco Mezzetti1, Andrea Da Re1, Alberto Bortolotti1, Luigi Rapezzi2, Vladymir A. Gribkov3 1 Dipartimento di Fisica dell’Universita and Istituto Nazionale di Fisica della Materia (INFM), Via del Paradiso 12, 44100 Ferrara, Italy 2 Ente per le Nuove Tecnologie, l’Energia e l’Ambiente (ENEA), C. R. Brasimone, 40032 Camugnano, Bologna, Italy 3 Institute of Plasma Physics and Laser Microfusion, Warsaw, Hery 23, Poland The application of a Fast Neutron Activation Analysis (FNAA) technique on samples of pure gold, irradiated by a plasma focus of 7 kJ, has been investigated. The reaction was the inelastic scattering of neutrons, 197Au(n,n'g)197Aum. To avoid problems connected with peculiar features of the neutron emission from this kind of source, a preliminary standardisation of the method has been carried out. The results obtained have a practical interest in view of possible applications to the technology of extraction of minerals. Close X |